LENOVO Server virtualization and management options
Lenovo Enviromental Monitoring Probe
Item No:
46M4113
EAN Code
883436087148
€ 175.00Excl. VAT

Bluelink Knowledge Base
- Introduction
- EAN Code:883436087148
Manufacturer data
- Features
- Purpose :Indoor
- Connectivity technology :Wired
- Humidity measuring range :0 - 80%
- Accuracy :1 °C
- Accuracy :5%
- Operational conditions
- Storage relative humidity (H-H) :10 - 90%
- Logistics data
- Harmonized System (HS) code :90318080
- Personal advice from bluelink
The Environmental Monitoring Probe (EMP) is used to report local temperature and humidity values and make that information available to management tools, such as IBM Systems Director Active Energy Manager (AEM).
The Environmental Monitoring Probe has the following characteristics:
- It connects to the Network Management Card (NMC) settings/sensor connection.
- Its temperature and humidity thresholds are easily set to trigger alarm notifications or shut down the protected system.
- Its status can be monitored from the IBM Systems Director AEM or from the Network Management Card web interface.
- It measures temperatures between 0 and 80°C (32 and 176°F) with an accuracy of ±1°C.
- It measures relative humidity between 10 and 90% with an accuracy of ±5%.
- It can be located away from the UPS by using a CAT5 network cable (up to 20 m (65.6 ft)).
- Its user-selectable alarm thresholds enable you to define acceptable temperature or humidity limits.
- It allows email notification through SMTP.
The Environmental Monitoring Probe has the following characteristics:
- It connects to the Network Management Card (NMC) settings/sensor connection.
- Its temperature and humidity thresholds are easily set to trigger alarm notifications or shut down the protected system.
- Its status can be monitored from the IBM Systems Director AEM or from the Network Management Card web interface.
- It measures temperatures between 0 and 80°C (32 and 176°F) with an accuracy of ±1°C.
- It measures relative humidity between 10 and 90% with an accuracy of ±5%.
- It can be located away from the UPS by using a CAT5 network cable (up to 20 m (65.6 ft)).
- Its user-selectable alarm thresholds enable you to define acceptable temperature or humidity limits.
- It allows email notification through SMTP.
- The product can be used with the following products or groups
- Item No.: 53951KX, 1500VA LCD 2U Rack UPS (23
- 53952KX, IBM 2200VA LCD 2U Rack UPS (23
- 53952KX, IBM 2200VA LCD 2U Rack UPS (23
- 53953KX, IBM 3000VA LCD 3U Rack UPS (23
- 53953KX, IBM 3000VA LCD 3U Rack UPS (23
- 53953KX, IBM 3000VA LCD 3U Rack UPS (23